Customer support

Report a problem

Three short parts: your details, what's wrong, and any photos. Nothing to type about the problem unless you want to, and it saves as you go. Have an account? Sign in and we'll fill in your details for you.

1Your details

On the label on the back. Needed for a problem with the unit.

2The problem

Which product?

Cal-Kit problems are sorted out on the phone. Call us and we'll talk it through. There's nothing to send here.

Call +1 850-807-7886 Email [email protected]

Could this affect safety?

For example a pressure reading that looks wrong, the motor moving when it shouldn't, or a test result that may be wrong.

If it might, we treat it as urgent: stop using the unit until we've talked. "Not sure" is fine.

What's wrong?

Tick everything that's happening. One report for several problems is fine.

The lung stopped moving, is stuck, or won't home

Before you go on

Stop testing, and don't keep restarting it or trying to re-home it: that can make it worse.

Take a photo of any error message on the screen, then leave the unit as it is until we've talked.

When did it happen?
Had the SCBA regulator been taken off just before it stopped?
Did the program show a message?
What has been tried so far? Tick any

"Pressure on the system" warning with nothing connected

Before you go on

Check nothing is connected to the head form, then switch the unit off and on and reopen the program, once.

If the warning comes back, don't run tests: send this report and we'll call you.

What was connected when you saw it?
When does it show?
Did switching it off and on clear it?

It won't turn on, or says there's no power

Before you go on

Check the power cable is pushed fully into the unit and the wall, and try another socket.

Please don't open the unit. If it was just shipped, a cable inside may have come loose, and we'll guide you.

What happens when you switch it on?
Did another wall socket make a difference?
When did it start?

The program can't find the OMNIcheck

Before you go on

Close the program. With the unit switched on, unplug both USB cables and plug them straight into the computer (not a hub), wait 10 seconds, then open the program again.

Has this computer worked with the unit before?
Were both USB cables in and the unit switched on before the program opened?
What does the program show? Tick any
Could you close the program?
Is anything new? Tick any
Has anything got it working again before? Tick any

A test fails, or gives a result that looks wrong

Before you go on

Don't put an SCBA back in service on this result until we've talked.

Keep the results you have, and don't repeat tests just to answer these questions. If you can, attach the test file or a photo of the result below.

Which test? Tick any
In the leak test, what does the pressure do?
Does it fail with every facepiece?
What's wrong with it? Tick any
How different are the retests?
Does anything make it pass? Tick any
Has the same SCBA been tried on another tester?

The program crashes, freezes or shows an error

Before you go on

If the program has lost the unit ("Connect" greyed out, "Resetting VI"), tick "The program can't find the OMNIcheck" too.

Write down or photograph any error code (like E-CAL-001), then close and reopen the program.

If it happens again, send this report.

When does it happen?
Did it show a message or error code?

It makes a strange noise

Before you go on

If it's getting louder or happening more often, stop testing until we've talked.

A short phone video with the sound helps most: attach it below or on the next page.

What does it sound like?
When do you hear it? Tick any
Is it getting worse?

It's damaged, or something looks wrong

Before you go on

Please don't use it until we've talked. Photos help most: attach them below.

If it just arrived, keep the box and the packing.

What do you see?
When did you notice?

Something else

What's the problem with?
A sentence or two is plenty: what you were doing and what happened.

3Photos and anything else

A photo of the screen or the unit helps most. Up to 90 MB here. A video can be added after you send.
Add the program version or more detail Optional
Change it if you like.
Steps that make it happen again, an error code (like E-CAL-001), anything you noticed.
Computer it runs on